HTPro.vn 27/4 Đình Phong Phú, Tăng Nhơn Phú B, Thủ Đức, Tp. Hồ Chí Minh
HLK-PM01 Chuyển Đổi AC-DC 220V-5V/3W Hi-link

  • HẾT HÀNG
    Đặt mua để có hàng sớm
  • Giá bán: 63.000 đ

  • Module nguồn chuyển đổi điện áp xoay chiều sang 1 chiều AC-DC input 220V output 5V/3W dùng trong các ứng dụng smartcontrol, smarthome với ưu thế nhỏ gọn và chống nhiễu tốt.




1.  Product features:

1. Meet UL, CE requirements,

2. Ultra-thin, ultra-small

2. All voltage input (AC: 90 ~ 264V)

3. Low ripple and low noise

4. Output overload and short circuit protection

5. High efficiency, high power density

6. The product is designed to meet the requirements of EMC and Safety Test

7. Low power consumption, environmental protection, no-load loss <0.1W

8.100% load aging and testing

9.1 year warranty perio

 

2. Environment Condition

Item Name

Technical Criteria

  Unit

Operation Temperature

-20—+60

Centigrade

Store Temperature

-40—+80

Centigrade

Relative humidity

5—95

%

Cooling way

Cooling by radiation

 

Atmospheric pressure

80—106

Kpa

Sea level elevation

≤2000

m

Vibration

Vibration coefficient 10~500Hz,2G10min./1cycle, 60min.each along X,Y,Z axes

 

 

 

3.Electrical Characteristic

1. Input characteristics (test at room temperature 20 Centigrade ).

 

Item Name

Technical Criteria

Unit

Rated input voltage

100-240

VAc

Input voltage range

90-264

VAc

Maximum input current

≤0.2

A

Input current surge

                  ≤10

A

maximum input voltage

≤270

VAc

Enter slow start

≤50

mS

Input Low Voltage Efficiency

Vin=110VAc,Output full-load≥69

%

Input High Voltage Efficiency

Vin=220VAc,output full-load≥70

%

Long-term reliability

MTBF≥100,000

h

Load rated output voltage

+5±0.1

VDC

Full rated output voltage

+5±0.2

VDC

Short-term maximum output current

≥1000

mA

The maximum output current for a long time

≥600

mA

Voltage Regulation

±0.2  

%

Load Regulation

                      ±0.5

%

Output ripple and noise

(mVp-p)

≤50

Rated input voltage, full load. Using 20MHz of bandwidth,

The load side 10uF and 0.1uF capacitor to be tested.

mV

Switch overshoot amplitude

(Rated input voltage and output load plus 10%)≤5

%VO

Output over-current protection

150-200% of the output maximum load

A

Output short circuit protection

Direct short circuit at the normal output, automatically resume normal operation after a short circuit removal

 

 

4.Safety Characteristics:

4.1 Products designed to meet UL, CE safety certification requirements.

 4.2 Safety and electromagnetic compatibility

Designed with the input of 0.5A UL certified insurance;

PCB board using double-sided copper clad plate production, material for the 94-V0 fire rating level;

  Ý kiến bạn đọc

Bạn đã không sử dụng Site, Bấm vào đây để duy trì trạng thái đăng nhập. Thời gian chờ: 60 giây